Revisions—MAN-06020 Rev. 003
MAN-06020 Rev. 003, 17 Dec 2019
The following procedures and sections were updated with Version 8.0 of the Panther System Service Manual.
New Topics
| Topic | Justification |
|---|---|
| Revisions — MAN-06020 Rev. 003 | To list revisions to the Panther Service Manual |
| Throughout — Fixed Grammatical, Verbiage, Spelling errors, and general flow for improved readability | Improve readability and experience |
| Throughout — Removed unneeded or duplicated words, sentences, and/or procedure steps | Improve readability and experience |
| Throughout — Updated formatting throughout the entire manual for consistency between text type, photos, diagrams, tables, and general formatting. | Improve readability and experience |
| Database Reduction Tool (DART) | New topic |
| Panther LINK Installation Qualification | New topic |
| Enable Dashboard on the Panther | New topic |
Revised Topics
Startup Topics
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| Essential Information | XE2 Ram Information | Improve Servicing |
Installation Procedures
System Overview
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| Priming and Waste Counting Theory | Revised content. | Improve Clarity. |
Packing and Relocation
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| None | None | None | N/A |
Maintenance Procedures
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| None | None | None | N/A |
Safety
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| Prevent Damage Electrostatic Discharge (ESD) | Revised to match Hologic standard. | None | Improve Clarity. |
Service Procedures
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| Panther Installation | Revised steps. | Improve Clarity. | |
| Software Installation | Revised steps. | Improve Clarity. | |
| Install System, Assays and Help Software - How to install Software | Revised steps. | Improve Clarity. | |
| Run Instrument Setup (Loading Firmware) | Revised steps. | Improve Clarity. | |
| Syscheck Verification |
Added. A Syscheck will need to be performed when replacing a Lumo or on a 3Yr-PM. |
Improve Servicing. Improve Clarity. |
|
| FSE Shield Software Login | Revised password section. | Improve Clarity. | |
| Dell OptiPlex XE3 Installation | Updated imaging and activation procedure. | Improve Servicing. | |
| Real-Time Fluorometer (RTF) Installation | Table with IVD Assays | Improve Servicing. | |
| Purging Results Manually | Revised procedure and added screenshots. | Improve Clarity. | |
| Enabling a Mapped Network Drive / LIS Fileshare | Revised procedure and added screenshots. | Improve Clarity. | |
| Disabling the Auto Shutoff Feature on the HP Officejet Printers | Removed the option to disable on the 6230 printer. | Improve Servicing. | |
| Real-Time Fluorometer (RTF) Installation | Fixed image togglers. | Improve Clarity. | |
| Dashboard - User Management | New images. | Improve Clarity. | |
| Dashboard - Work Cell Management | New images. | Improve Clarity. | |
| Dashboard - Threshold Configuration | New images. | Improve Clarity. | |
| Dashboard - Feature Management | New images. | Improve Clarity. | |
| Dashboard - Instrument Management | New images. | Improve Clarity. | |
| Dashboard - Manage Remote Data Access | New images. | Improve Clarity. | |
| Dashboard - Network Configuration | New images. | Improve Clarity. | |
| Dashboard - Client Management | New images. | Improve Clarity. | |
| Dashboard - Administration | New images. | Improve Clarity. | |
| Universal Fluid Service Procedures | Fixed links. | Improve Usability. |
Modules
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| None | None | None | N/A |
Removal and Replacement Procedures
| Topic | Additions | Deletions | Justification |
|---|---|---|---|
| Fusion Cartridge Carousel Removal and Replacement | Note - Remember to install the drawer trim from the module being replaced and place it onto the module biemg installed | Improve servicing. | |
| Luminometer Photomultiplier Tube (PMT) Assembly Removal and Replacement | Change to the correct mm to 2 and added 2,5mm in tools. | Improve servicing. | |
| Panther Pipettor Arm Removal and Replacement | Fixed step 6 toggler. | Improve servicing. | |
| Auto Detect 1 and 2 LCMP Removal and Replacement | Updated the time required. | Improve servicing. | |
| Peristaltic Pump Assembly Removal and Replacement | Revised the procedure with new screenshots. | Improve servicing. | |
| OdorCarb Vacuum Filter Removal and Replacement | Added what is affected section. | Improve servicing. |
Deleted Topics
| Topic | Justification |
|---|---|
button at the top of the page to send feedback, comments, or change requests.